Benchtop design exterior dimensions 90 x 54 x 62 cm39 x 30 cm (1170 cm2) exposure area1 air-cooled 1700 W xenon lampEasy-to-use touch screen user interface with 13 selectable languagesDirect setting and control of irradiance at 300-400 nm (incl. 340 nm) or 300-800 nm (incl. Lux)Direct setting and control of Black Standard Temperature (BST), BPT optionalDisplay of test chamber temperatureDirect setting of tolerance ranges for each test parameter for optimum test controlDisplay of diagnostic messages10 free programmable tests possible with up to 12 phasesPre-programmed polymer and coatings standards for Quick-startersControl panel tilts for comfortable ergonomic operationHorizontal 1170 cm2 exposure area, for multiple flat or 3-D specimensPremium sunlight simulation according to CIE85 reference sunLamp cassette with aluminum reflector, lamp connections and filter slotOuter filter non-aging uncoated quartzIrradiance range 30-65 W/m2 (300-400 nm); 0.26-0.62 W/m2 (340 nm) or 250-765 W/m2 (300-800nm); 45-130 klx (Lux)BST range 45-100 °CBST sensor design according to ISO 4892-1Ethernet interface for network connections. See optional XenoTouch Software Add-ons 1, 2, and 3 (“Remote Control“, “E-Mail Service“, “Online Monitoring“)"Switch-off modes: radiant exposure, light exposure time or total operating timeAdvanced auto-start functionsData output via RS232 or memory cardInternal memory chip for storing instrument datatransport cartMANUFACTURE DATE 11-2022Serial # 2210498Power: 230V (L,N,PE) 50/60hzHIGHLIGHTED OPTIONS BELOW INCLUDED
Daylight filterWindow Glass filterSolar ID 65 filterStore Light filterSunCool Chiller for testing at low temperatures down to 15C during light cyclesSunSpray: 40 L specimen spray system for testing the weather resistance of materials, e.g. paints, plastics or building materialsSunFlood:40 L temperature controlled immersion system for testing the weather resistance of materials, e.g. paints, plastics or building materialsWater-cooled specimen table for exposure of thermo-sensitive samplesICH-D10/20/30 powder sample holders for preparation of 1-3 mm powder samples (Pharmaceuticals)SunCal BB 300-400 BST sensor for calibration of irradiance in W/m² in the wavelength range 300-400 nm and for calibration of BST in °CSunCal WB 300-800 BST sensor for calibration of irradiance in W/m² in the wavelength range 300-800 nm and for calibration of BST in °CSunCal Lux BST - Calibrated Lux-Sensor for calibration (via IBM compatible PC) of illuminance (lx) and radiant exposure (lxh), combined with calibrated BST sensor for calibration of Black Standard Temperature in °CHumidity sensor